Analisis Penghematan Penggunaan Energi Listrik Berbasis Fuzzy pada Hotel

Authors

  • Rifqi Wibowo Universitas Islam Sultan Agung
  • Sri Artini Dwi Prasetyowati Universitas Islam Sultan Agung
  • Agus Adhi Nugroho Universitas Islam Sultan Agung

DOI:

https://doi.org/10.55606/jutiti.v5i2.5839

Keywords:

Energy Consumption Intensity, Energy Efficiency, Energy Management, Energy Saving Opportunities, Fuzzy

Abstract

Electricity is an important necessity, but its use must be managed wisely to avoid waste and negative environmental impacts. Energy-saving programs implemented in buildings encourage consumers to use energy more efficiently, reduce wasteful consumption that leads to inflated electricity bills, and serve as an initial step in overall energy management to lower total energy costs. Hotel Grand Dian Bumiayu showed an initial IKE of 27.77 kWh/m²/year. This figure, with a total energy consumption of 144,752.01 kWh/year, falls into the highly efficient category. This means the building's energy usage is already considered optimal compared to existing standards. Fuzzification calculations, using data from September 2023, yielded a DeFuzzification value of 12.858. This value is within the IKE range for the "Moderately Efficient" criterion (12.08 – 19.17), meaning that, based on this analysis, energy usage during that period was classified as moderately efficient. A detailed energy audit identified four types of loads that significantly contributed to the hotel's power consumption. From this analysis, it was revealed that the largest electricity consumption (kWh/year) originated from the air conditioning system, accounting for 77%. Following the air conditioning system, the lighting system ranked second with 14% of the total consumption. Then, office equipment contributed 5%, and the smallest electricity consumption was recorded for utilities, at 4%. After implementing Energy Saving Opportunities (PHE), the final Energy Consumption Intensity (IKE) was recorded at 30,013.75 kWh/m²/year. This IKE value indicates that energy consumption is highly efficient. This result is quite reasonable, considering that the initial IKE even before the analysis of energy-saving opportunities was conducted, was already in the efficient category.

Downloads

Download data is not yet available.

References

Amanat, S., Menteri, P., & Listrik, P. P. (2012). Panduan penghematan energi di gedung pemerintah. 13.

Badan Standardisasi Nasional. (2011). Prosedur audit energi (pp. 1–16).

Balavignesh, S., Kumar, C., Ueda, S., & Senjyu, T. (2023). Optimization-based optimal energy management system for smart home in smart grid. Energy Reports, 10, 3733–3756. https://doi.org/10.1016/j.egyr.2023.10.037

Cahyanto, A., Nisworo, S., & Pravitasari, D. (2021). Audit penggunaan energi listrik pada air conditioner di rumah sakit tipe C (Studi kasus: RSUD dr. R. Soetrasno Rembang Jawa Tengah). THETA OMEGA: Journal of Electrical Engineering, 2(2), 53–56.

Diaz-Acevedo, J. A., Grisales-Noreña, L. F., & Escobar, A. (2019). A method for estimating electricity consumption patterns of buildings to implement energy management systems. Journal of Building Engineering, 25, 100774. https://doi.org/10.1016/j.jobe.2019.100774

Fitriani, I. (2017). Evaluasi efisiensi energi listrik pada bangunan rumah sakit Dr. Sayidiman Kabupaten Magetan (pp. 9–10).

Gunawan, W. (2018). Mengurangi konsumsi energi dengan audit dan manajemen energi pada ruang kendali (Studi kasus di PT PWI). Journal Industrial Services, 4(1). https://doi.org/10.36055/jiss.v4i1.4099

Gunawan, W., Juniarti, A. D., & Rosihan, D. (2022). Audit energi listrik pada bangunan gedung kampus 1 Universitas Banten Jaya (Studi kasus Gedung 4 Universitas Banten Jaya). Jurnal InTent, 5(2), 50–67.

Ikhsan, M., & Saputra, M. (2018). Audit energi sebagai upaya proses efisiensi pemakaian energi listrik di kampus Universitas Teuku Umar (UTU) Meulaboh. Jurnal Mekanova: Mekanikal, Inovasi dan Teknologi, 2(3), 136–146.

Indonesia, S. N. (2000). Prosedur audit energi pada bangunan gedung. SNI 03-6196-2000, 1–14.

Informasi, S., Syamsudin, M., & Yuniarto, W. (2017). Penentuan prioritas efisiensi energi listrik menggunakan metode fuzzy logic. Prosiding SISFOTEK, 3584, 124–128.

Iryani, B. S., et al. (2024). Tingkat penghunian kamar hotel 2023. Journal of Physics A: Mathematical and Theoretical, 44(8), 1–14. https://doi.org/10.1016/j.regsciurbeco.2008.06.005

Jamal, J., Marlina, M., & Dwi, F. (2019). Audit energi dan analisis peluang penghematan energi listrik pada bagian produksi di PT. EPFM Makassar. Jurnal Sinergi Jurusan Teknik Mesin, 17(1), 42. https://doi.org/10.31963/sinergi.v17i1.1591

Kementerian ESDM. (2012). Manajemen energi. Peraturan Menteri Energi dan Sumber Daya Mineral Republik Indonesia Nomor 14 Tahun 2012, 1–19.

Mangaku, C. J. F., Patras, L. S., & Rumbayan, M. (2021). Analisa audit energi RS. GMIBM Monompia Kotamobagu. 1–10.

Muhammad Rigadho Suprayogi. (2014). Analisis audit energi pada beban HVAC (Heat, Ventilation, and Condition) di Rumah Sakit Umum Daerah Dr. Saiful Anwar Malang.

Ogunjuyigbe, A. S. O., Ayodele, T. R., & Akinola, O. A. (2017). User satisfaction-induced demand side load management in residential buildings with user budget constraint. Applied Energy, 187, 352–366. https://doi.org/10.1016/j.apenergy.2016.11.071

Program, M., Teknik, S., Teknik, F., Udayana, U., Program, D., Teknik, S., Teknik, F., Udayana, U., Kampus, J., & Jimbaran, B. (2022). Studi manajemen energi listrik dan analisis peluang penghematan konsumsi energi listrik pada gedung pengadilan negeri Denpasar. 9(2), 120–127.

Rengganis. (2019). Audit energi pada perkantoran di Jakarta Selatan. 6.

Rezaldi Lagonggan, G. M. C. M., & Lily Setyowati Patras. (2020). Studi efisiensi penggunaan energi listrik di Perseroan Terbatas Multi Nabati Sulawesi Unit Maleo. E-journal Teknik Elektro dan Komputer.

Rosano, A. (2020). Audit energi listrik pada gedung Menara “MBM” PT Bank XYZ Kantor Regional Cirebon. INSANTEK-Jurnal Inovasi dan Sains Teknik Elektro, 1(1), 34–39.

Safitra, A. G., & Putra, M. D. A. P. (2020). Konservasi energi sektor bangunan rumah sakit Cempaka Putih Permata Surabaya. Jurnal Technopreneur (JTech), 8(2), 97–102. https://doi.org/10.30869/jtech.v8i2.617

Saing, B., Krismahariyanto, M., Fahdillah, N., & Universitas Bhayangkara Jakarta Raya. (2019). Audit awal energi listrik RS Kartika Husada Tambun Bungaran. 1*(1), 25–33.

SNI 03-6197-2000. (2000). Standar Nasional Indonesia Badan Standardisasi Nasional konservasi energi pada sistem pencahayaan. S.A.

Wardani, A. R., Nasution, Y. N., & Amijaya, F. D. T. (2017). Aplikasi logika fuzzy dalam mengoptimalkan produksi minyak kelapa sawit di PT. Waru Kaltim Plantation menggunakan metode Mamdani. Informatika Mulawarman: Jurnal Ilmiah Ilmu Komputer, 12(2), 94. https://doi.org/10.30872/jim.v12i2.651

Yasir Pohan, M. (2022). Analisis penggunaan energi listrik di Rumah Sakit Islam Malahayati Medan.

Downloads

Published

2025-09-10

How to Cite

Wibowo, R., Sri Artini Dwi Prasetyowati, & Agus Adhi Nugroho. (2025). Analisis Penghematan Penggunaan Energi Listrik Berbasis Fuzzy pada Hotel. Jurnal Teknik Informatika Dan Teknologi Informasi, 5(2), 735–745. https://doi.org/10.55606/jutiti.v5i2.5839

Similar Articles